The fixes a failed report asks for, with the figures
Send the failed report
Tell us the address and what the report flagged, and we reply with prices line by line.
The usual list, priced where we can
These are the items that come up again and again on inspections of houses that burn wood or pellets in Orange and the cities around it. The first four carry a figure on this site; the rest depend on the chimney in front of us.
- Water getting in at the crown, flashing or brick: $575 to $3,450.
- A wide chimney trapping water on its uphill side: $460 to $1,040 for the diverter, $690 to $1,700 with new flashing at the same time.
- An open fireplace converted to gas heat: $2,850 to $5,750 for the insert and its vent.
- Hardened tar in the flue: a sweep from $430, more passes if the deposit is thick.
- Wood stove with no liner, cracked crown, broken damper, rusted chase top: priced in writing for that chimney.
- No cap or a rusted one with no spark screen: quoted after we measure.
Why some fixes have no fixed figure
A liner for a wood stove depends on the height of the chimney, the size the stove needs, and whether the old tiles have to be broken out to fit it. A crown can need a coat of sealer or a full recast. A damper can need a new handle or a new plate. Two houses on the same street can be far apart on these, so we look first and then put a number on paper.
That number comes as a line on a written quote, with photos of the problem, before any work starts.
What gets fixed first
Anything that can start a fire or push smoke into the house goes to the top: a stove venting into an unlined masonry flue, thick tar, a cracked tile next to wood framing. Water problems come next, because rain soaks brick and rusts dampers through the winter. Cosmetic items wait.
If the report came from someone else, send it to us. We confirm the findings on site and price the same list, so you can compare.
Published repair prices
Our own figures for the code fixes that come up most. Anything missing from this table is priced in writing for your chimney.
- Finding where water enters and stopping it
- $575 to $3,450
- Diverter on the uphill side of a broad stack
- $460 to $1,040
- Diverter plus a fresh set of metal flashing
- $690 to $1,700
- Converting an open hearth to a sealed gas heater
- $2,850 to $5,750
- Camera run to confirm the work afterwards
- $400
- Spark-screened top for an open flue
- Quoted after we measure
Questions after a failed report
My wood stove has no liner. Is that a code issue?
A stove set into a fireplace needs a properly sized flue to the top of the chimney. Venting into the open masonry is a common failure, and a liner is the usual fix. We price it after measuring.
Can I keep burning until the repairs are done?
Depends on the finding. Tar and cracked tiles near framing mean stop now. A missing cap or a slow leak usually does not. The report says which is which.
Do I need to fix everything on the list at once?
No. Safety items first, water next, the rest when it suits you. We price each line separately so you can order them.
Will you inspect again after the work?
Yes. A Level 2 after the repairs gives you camera footage of the finished flue, useful for a buyer, an insurer or your own records.
Do your prices include the cap screen size my stove needs?
Caps are quoted after we measure, since sizes and metals differ. We confirm the right one for your flue on the roof and the quote shows it.
Turn a failed report into a priced list
Send the address and the findings through the contact page, and we answer with a line-by-line quote.
Call (657) 233-4417